SECTION 3: SETUP CONFIGURATION
Friendly name
Enter whatever friendly name for the DI and DO that you prefer. This feature is useful when DI and/or DO is activated, especially if
there are multiple device servers managed by your application program.
DI Trigger type
Select the DI device trigger type for the device installed (normally open (NO) or normally closed (NC)).
DI Re-arm period
The DI re-arm period sets the detection time interval for the event publisher. If “0” is specied, the device reports an event every
time a DI event is sensed. If “10” is specied, the device must sense DIs events within 10 seconds before reporting the event.
DO Hold period
The DO hold period sets the duration the DO is activated. If “0” is entered, the DO remains active until it is manually turned o. If
“10” is entered, DO is activated for 10 seconds.
Apply and Reset
After making conguration changes, click Apply to save the settings, or click Reset to revert to the previous settings.
Example
DI#1 and DO#1 are congured to sense and report the same event. The DI#1 trigger type is Normal Open. Suddenly DI#1 is triggered
by any kind of event.
Expected Response: The status of DO#1 will change from OFF to ON if the default setting is OFF. The status of DI#1 will change
from OPEN to CLOSE.
3.6.2 UART
Your camera or encoder may include up to two UART interface ports, identied as UART1 and UART2. To congure these UART
interfaces, go to SETUP > IO Conguration > UART