800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN
7
6
GK Actuators, Multi-Function Technolo
gy
Dimensions with 2-Way Valve
D
B
C
A
BHC
D
imensions
(
Inches
)
N
o
n-Fail
Safe (psi)
)
V
alve
S
ize
A
B
C
D
(
Max
)
BH
C
G
K
F680
HD
3”
1.
69
9
.
00
9
.
00
21.
03
6
.
00
200
F
6100HD
U
4”
1.92
9
.00 9.00 21.5
3
7.50 5
0
F
6125HDU 5
2
.08
9
.00 9.00 22.5
3
8.50 5
0
F61
5
0HDU
6”
2
.
19
9
.
00
9
.
00
22
.5
6
9
.5
0
5
0
F
650-150
S
HP
2”
1.75
9
.00 9.00 20.0
3
4.75
2
85
F
665-150
S
HP
2
½” 1.88
9
.00 9.00 20.5
3
5
.50
2
85
F
680-150
S
HP
3”
1.92
9
.00 9.00 21.0
3
6.00
2
85
F
6100-150
S
HP
4”
2
.13
9
.00 9.00 21.5
3
7.50
1
50
F
650-300
S
HP
2”
1
.75
9
.
00
9
.
00
20
.
03
5
.
00
28
5
F
665-300
S
HP
2½”
1
.
88
9
.
00
9
.
00
20
.5
3
5
.
88
28
5
F
680-300SHP
3”
1.92
9
.00 9.00 21.0
3
6.63
2
85
F
6100-300
S
HP
4
2
.13
9
.00 9.00 21.5
3
7.88
1
50
F
6100VI
C
4”
4
.63 8.63 8.6
3
16.00 -
2
00
AM
_
GM
_
LineRevise
d
Technical Data GKX24-MFT-X1
P
ower suppl
y
24VAC ±20% 50/60H
z
24VD
C
±10
%
P
ower consum
p
tio
n
12W
(
3W
)
Trans
f
ormer sizin
g
21VA
(
class 2 power source
)
Electrical connectio
n
18 GA
p
lenum rated cabl
e
½
" con
d
u
i
t connecto
r
protecte
d
NEMA
2
(IP
5
4)
3 ft [1m] 10 ft [3m] 16 ft [5m
]
Overload
p
rotectio
n
electronic throughout 0 to 95 rotatio
n
Operation range
Y
2 to 10 VDC, 4 to 20mA (default
)
variable (VD
C
,PWM, fl oating point, on/off
)
Input impedanc
e
100
k
Ω (0.1 mA), 500
Ω
150
0
Ω
(PWM, fl oating point, on/off
)
Feedback output
U
2 to 10VDC, 0.5mA max, VDC variabl
e
Angle of rotation max. 95°, ad
j
ustable with mechanical stop
electronicall
y
variabl
e
Direction of rotatio
n
rever
s
ible with
s
witch
Fail-safe
p
ositio
n
ad
j
ustable with dial or tool 0 to 100% in 10%
increment
s
P
o
s
ition indication refl ective visual indicator (snap-on
)
Manual overrid
e
external push butto
n
R
unnin
g
time
normal operatio
n
f
ail-
s
a
fe
95 seconds (default), variable 90 to 150 second
s
35
s
econd
s
Humidity 5 to 95% RH non-condensing (EN 60730-1
)
Ambient tem
p
eratur
e
-22°F to +122°F [-30°C to +50°C
]
S
torage temperatur
e
-40°F to +176°F
[
-40°C to +80°C
]
Housin
g
NEMA2, IP54, UL enclosure t
y
pe
2
Housing materia
l
UL94-5V
A
Agenc
y
lis
t
cULus acc. to UL 60730-1A
/
-2-1
4
CAN
/
CSA E60730-1:0
2
CE acc. to 2004
/
108
/
EEC and 2006
/
95
/
E
C
Noi
s
e level < 45d
B
(A)
S
ervicing maintenance fre
e
Qualit
y
standar
d
I
SO
900
1
N
o
t
e
: GKR Actuators are on 2-wa
y
valves
GKX Actuators are on 3-way valves
Dimensions with 3-Way Valve
Dimensions
(
Inches
)
N
on-Fail
S
afe
(
psi
)
Valv
e
S
ize
A
B
C
D(
Max
)
BH
C
G
K
2
*
G
K
F780HD
U
3”
5.50 7.20 7.2
0
16.7
8
6.00 20
0
F7100HD
U
4”
2.05 8.00 8.0
0
17.0
0
7
.50 5
0
F7125HD
U
5
2.14 8.00 8.0
0
17.5
0
8
.50 5
0
F7150HD
U
6”
2.19 8.00 8.0
0
22.5
0
9.50 5
0
F750-150SH
P
2”
4
.
50
6
.2
5
6
.2
5
17.
03
4.7
5
1
50
F765-150
S
H
P
2
½” 5.00 6.88 6.8
8
17.5
3
5
.50 15
0
F780-150SH
P
3”
5.50 7.42 7.4
2
18.0
3
6.00 15
0
F765VI
C
2
½” 3.77 6.88 6.8
8
15.0
0
-
5
0
F780VIC
3”
3.77 7.42 7.4
2
15.0
0
-
20
0
F7100VI
C
4”
4
.
63
8
.
63
8
.
63
1
6
.
00
-
50
Single_Butterfl y
1
0
0
D
AB
C
Model
s
G
KRX24-MFT-X1
G
KRB24-3-5
GKX24-MFT-X1
O
50904 - 02/12 - Subject to change. © Belimo Aircontrols
(
USA
)
, Inc.
Vista de página 24